Dimensions are in inches (millimeters). Datasheet & Specifications. This arbitrary waveform generator can generate signals from -12 V to +12 V and uses a fractional. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. For information about the device specifications, refer to the NI PXIe-7976R Specifications,Buy 784068-01 - Ni - Screw Terminal Connector Kit, PXIe-4136/7/8/9 SMUs. Likewise, the connector kit that ships with these new SMU's now includes 4 additional. SCREW TERMINAL CONNECTOR KIT FOR. PXI System Source Measure Units. ni. Standard Package. 01 1 0. com | PXIe-4136 Specifications Maximum measure rate to host 1. •Source Adapt: Yes. Part Number: 198666E-01L, 198754B-01L, 780321-01. This arbitrary waveform generator can generate signals from -12 V to +12 V and uses a fractional. PXIe-4136 Pinout(s) Regulatory . Buy 783760-01 - Ni - Source Measure Unit SMU, 1-Channel, 4-Quadrant, PXIe-4136, ± 1A, ± 200V, 20W. The PXIe-4136 system source measure unit (SMU) delivers high power, precision, and speed and features 4-quadrant operation. National Instruments PXIe-4136 Datasheet (pdf) National Instruments PXIe-4137 Datasheet (pdf) National Instruments PXIe-4138 Datasheet (pdf)PXIe-4141 - Price and Info. 06. PXI機箱可相容PXI Peripheral Module或Hybrid Slot-Compatible PXI Module。. •Current Sesitivity: 1 pA. If you need a specific firmware or series relating to PXIE-1062Q, we probably have it. Manuals. Mark as New; Bookmark; Subscribe; Mute; Subscribe to RSS Feed; Permalink; Print; Report to a Moderator; Labels: Current; Current Source; PXIe-4136; SMU;The PXIe‑1071 is designed for a wide range of test and measurement applications and provides a high-bandwidth backplane. 如果這些卡中的任何一個檢測到遠程感測端子連接不當,它將關閉輸出並進入錯誤狀態。. PXIe-4136 Pinout(s) Regulatory . Also for: Pxie-4137. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. The module supports DMA streaming between the host PC and SMU, so you can stream large waveforms. The PXIe-4136 system source measure unit (SMU) delivers high power, precision, and speed and features 4-quadrant operation. Call for Best Pricing. Ideal for lab characterization, board-level testing, and manufacturing test environments, it is proficient at working with integrated circuits ( National Instruments PXIe-4136 | In Stock. Are you in EU? Call: +44 1782 576800. element14 Malaysia offers special pricing, same day dispatch, fast delivery, wide inventory, datasheets & technical support. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Oscilloscope cars: PXIE-5122,5114,5124,5105 and etc. PXIe-4136 Calibration Procedure(s) Visual Diagrams . PXIe-4136 PXIe-4137 PXIe-4138 PXIe-4139 PXIe-4140. M9010A 10-slot PXIe chassis, Gen 3 delivers industry-leading sound power levels combined with exceptional per-slot cooling to meet the demands of high-performance PXIe modules. Buy 784068-01 - Ni - Screw Terminal Connector Kit, PXIe-4136/7/8/9 SMUs. are not included with this equipment unless listed in the above stock item description. PXIe-4162 configured for fast transient response. Manufacturer Standard Lead Time. To access NI 4136/4137 documentation, navigate to Start»All Programs»National Instruments »NI-DCPower»Documentation . National Instruments PXIe-4136 Datasheet (pdf) National Instruments PXIe-4137 Datasheet (pdf) National Instruments PXIe-4138 Datasheet (pdf)There is a safety interlock test procedure in the Getting Started Guide for the PXIe-4136 using the NI-DCPower Soft Front Panel. Phone: (217) 352-9330. However, the connections will be made as seen in Figure 2. The solution is limited to a maximum output frequency of 5 kHz. Standard Package: 1: Co-Browse. PXI System Source Measure Units PXIe-4135, PXIe-4136, PXIe-4137, PXIe-4138, and PXIe-4139 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • SourceAdapt digital control loop technology • Four-quadrant source and. Manuals and User Guides for NI PXIe-4136. PXIe, 125 MHz, 250 MS/s, 8-Bit PXI Oscilloscope. For the NI PXIe-8135 specifications and details about the differences between the PXIe-8135 Windows 10 and other models, visit apexwaves. Configuration: •Number of SMU Channels: 4. 784782-01. 5 V to 60 V. 01 1 0. Price: Contact a sales representative for a quote. PXIe, 96-Channel, 5 V, TTL/CMOS, 24 mA PXI Digital I/O Module. 288. NI PXIe-4141 Source Measure Unit (SMU) Stock # 95045-17 Add to Cart. Attribute. 1 1 0. 1 Offset Accuracy, Tcal +/- 5 degrees (pA) 6 200 100 200 100 Offset Accuracy, Tcal +/- 1 degree (pA) 5 - 40 - 40Price may vary with addition of accessories and services. e絡盟 Hong Kong offers special pricing, same day dispatch, fast delivery, wide inventory, datasheets & technical support. PXIe-2529 Specifications. 8 MS/s per channel, continuous, nominal Maximum source update rate 13 100,000 updates/s, nominal 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。 Price does not include custom duties and taxes. Newark offers fast quotes, same day shipping, fast delivery, wide inventory, datasheets & technical support. PXIe, x8, MXI-Express Interface, PXI Remote Control Module. 6 T cal is the internal device temperature recorded by the PXIe-4136 at the completion of the last self-calibration. PXIe, 32 AI (16-Bit, 2 MS/s), 4 AO, 48 DIO, PXI Multifunction I/O Module. Guaranteed | (888) 88-SOURCE | applies to the PXIe-4136 (40W) when used with any chassis and only applies to the PXIe-4136 (40W) when used with a chassis with slot cooling capacity <58W. I am using a PXIe-4136 and LabVIEW™ is detecting a "hazardous voltage" even though I am within the safety limit. com. National Instruments PXIe-4139 Source Measure Unit (SMU) Configuration: •Number of SMU Channels: 1. Also for: Pxie-4137. NI PXIe-4138/4139 Getting Started Guide (this document) 5. f) Tie the cable drain wire to the grounding screw. PXIe-4339: PXIe-5673E (3. 1 Offset Accuracy, Tcal +/- 5 degrees (pA) 6 200 100 200 100 Offset Accuracy, Tcal +/- 1 degree (pA) 5 - 40 - 40From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. PXIe, -200 V, -1 A (DC)/-3 A (Pulsed), 1 pA / 100 fA Precision System PXI Source Measure Unit. NI PXIe-4136 Calibration Manual (26 pages) CALIBRATION PROCEDURE, SINGLE-Channel SYSTEM SOURCE MEASURE UNIT (SMU) Brand: NI. This chassis is designed to operate quietly, since it can work at 43. Newark offers fast quotes, same day shipping, fast delivery, wide inventory, datasheets & technical support. The PXIe-6672 and PXI-6683 modules contain a temperature-compensated crystal oscillator (TCXO) which can achieve accuracies better than 4 ppm. Entuk maksimal saka. My PXIe-4135 is detecting a hazardous voltage at the output. The solution is limited to a maximum output frequency of 5 kHz. 01 1 0. This document contains specifications for the PXIe-1083 chassis. 通常當發生此錯誤時,不正確的連接包括反轉檢測端子的極性、將檢測引線短接在一起或本地檢測 HI 或 LO 的連接鬆動。. The PXIe-3610 DAC is shown below in Figure 6, and the PXIe-3630 ADC is shown in Figure 7. Refer to theThe PXIe‑4136 features 4-quadrant operation. com. 1 % or so). National Instruments PXIe-4136 Datasheet (pdf) National Instruments PXIe-4137 Datasheet (pdf) National Instruments PXIe-4138 Datasheet (pdf)PXIe-4138 - Price and Info. PXIe-6570 Front Panel The PXIe-6570 front panel has a single 68-pin VHDCI Digital Data and Control (DDC) connector. The module supports DMA streaming between the host PC and SMU, so you can stream. PXIe-2529 User Manual(s) PXIe-2529 Getting Started Guide(s) Visual Diagrams . National Instruments PXIe-4136. PXIe-4135 PXIe-4136 PXIe-4137 PXIe-4138 PXIe-4139 Maximum Voltage (V) 200 200 200 60 60 Maximum DC Current (A) 1 1 1 3 3 Maximum Pulse Current (A) 3 1 3 3 10 Current Sensitivity (pA) 0. Prices shown are standard retail prices, orders placed will have contract pricing applied when processed. 3 N · m (2. The NI PXIe-4136 has Free Ground Shipping and a 1-3 Year Warranty, depending on New, Reconditioned, Used, or Repair Status of the model. Fax: (240) 376-1381. used. 1 1 0. Price may vary with addition of accessories and services. ). 5 (patch) PXIe-4136: PXIe-4137: PXIe-5668R: Calibration Executive 3. Question: What is the PXIe-4137 module’s current sensitivity?. PXIe-4136 Calibration Procedure(s) Visual Diagrams . It can source or sink up to 20 W of DC power and measure voltage, current, and resistance. It is installed in a PXI chassis and uses a PCI Express‑to‑PCI bridge to interface with an. The module supports DMA streaming between the host PC and SMU, so you can stream. PXIE-1088 9-SLOT 3U PXI EXPRESS. 7 lb · in. 01 1 0. 1. The PXIe-4139 (Part Number: 782856-02) Source Measure Unit highlights Guard and Sense terminals on the output connector. Show all topics. 8 MS/s per channel, continuous, nominal Maximum source update rate 13 100,000 updates/s, nominalPXIe-4136 Specifications | National Instruments | 13 Artisan Technology Group - Quality Instrumentation. All other SMUs will have a non-zero current which will be sinked in the SMU. Order today, ships today. Part Number(s): 783760-01 | Repair Evaluation: $150. Newark offers fast quotes, same day shipping, fast delivery, wide inventory, datasheets & technical support. It is also possible to use Sense terminals when remote sense is empowered to compensate for current-resistance loss. Each channel has an Analog to Digital Converter. With 24-bit analog inputs and IEPE constant current signal conditioning. The glyphs underneath each slot are visually different to PXI so that there is a clear indication this is a PXIe slot, PXIe uses a dark background with white slot numbering whereas PXI uses a light background with dark slot numbering. National Instruments PXIe-4139 Source Measure Unit (SMU) Configuration: •Number of SMU Channels: 1. PXIe, 32 AI (16-Bit, 2 MS/s), 4 AO, 48 DIO, PXI Multifunction I/O Module. com Amplicon. Phone: (217) 352-9330. SMU specifications take precedence if the SMU model is rated for lower voltage. Likewise, the connector kit that ships with these new SMU's now includes 4 additional POGO pins. All specifications are subject to change without notice. To meet XI Express cooling requirements, this model features 30 Watt per slot cooling. Work with our experts to sustain your critical applications. The DC coupled device has a timing resolution of 10 ns,. PXIe-4135 PXIe-4136 PXIe-4137 PXIe-4138 PXIe-4139 Maximum Voltage (V) 200 200 200 60 60 Maximum DC Current (A) 1 1 1 3 3 Maximum Pulse Current (A) 3 1 3 3 10 Current Sensitivity (pA) 0. Please call or email us with your request. Screw Terminal Connector Kit, Smu; Accessory Type:Screw Terminal Connector Kit; For Use With:Ni Pxie-4136/7/8/9 Smus; Product Range:- Rohs Compliant: Yes |Ni 784068-01. The block diagram for the signal calculation is shown by the. Contact us with questions for pricing. Unit price does not include Import duty, VAT, or Sales Tax. Figure 3. The NI PXIe-5122 has Free Ground Shipping and a 1-3 Year Warranty, depending on New, Reconditioned, Used, or Repair Status of the model. The ambient temperature of a PXI system is defined as the temperature. 96. National Instruments PXIe-6570 Frequently Asked Questions . for the PXIe-4136. 1. Part Number: 782435-01. Newark Part No. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。Model Number(s): PXIe-4136 Product Category: Electrical equipment for measurement, control, and laboratory use. Engineers use NI PXI to build high-performance, mixed-measurement systems for validation and production test. It is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. SMU specifications take precedence if the SMU model is rated for lower voltage. Overview. •Current Sesitivity: 1 pA. Ensure that the environment you are using the PXIe-4163 in meets the following specifications: ni. The following table lists the minimum current levels of SMU devices. The module supports DMA streaming between the host PC and SMU, so you can stream large waveforms and measurement data at the full update rate and. Unit price does not include Import duty, VAT, or Sales Tax. element14 Philippines offers special pricing, same day dispatch, fast delivery, wide inventory, datasheets & technical support. All prices are shown in USD. PXIe, ±200 V, ±1 A DC, 20 W DC, 1 pA System PXI Source Measure Unit The PXIe-4136 system source measure unit (SMU) delivers high power, precision, and speed and features 4-quadrant operation. Measured at the end of the 1 m SHDB62M. The user can utilize Guard terminals to actualize guarding strategies in cabling and test installations. PXIe Bus Enumeration. 2770-786818-01. or Best Offer. 仅对于pxie-414x,pxie-4136 / 4137和pxie-4138 / 9,您可以在恒流模式下将电流值设置为0a。这将使smu看上去像“开路”,不会有电流从dut流入smu。注意:只有pxie-414x,pxie-4136 / 4137和pxie-4138 / 9允许您将电流值设置为0。所有其他ni smu的最小电流值通常为电流范围的2%。The FGEN VI together with the Signal Calculation VI both found under the Forum Sine Wave Generation with SMU link allows you to use a NI 414x, NI 4135/4136/4137/4138/4139 as a function generator. Price does not include custom duties and taxes. Open a service request. The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 40 W of DC power. Remote sense can be enabled or disabled using the niDCPower Configure Sense VI on a per output basis for channels that support this feature. PXIe-4139 PXIe, ±60 V, ±3 A (DC)/±10 A (Pulsed) Precision System PXI Source Measure Unit These specifications apply to the PXIe-4139. •Current Range: -10 A to 10 A. Manufacturer Product Number. Descriptions of National Instruments 784068-01 provided by its distributors. the PXIe-4136. PXIe-5413 PXIe-5423. Products Manufacturers Services Solutions Resources Promotions About Us. It is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. You use it for processor-intensive, modular instrumentation, and data acquisition applications. PXIe-4135 PXIe-4136 PXIe-4137 PXIe-4138 PXIe-4139 Maximum Voltage (V) 200 200 200 60 60 Maximum DC Current (A) 1 1 1 3 3 Maximum Pulse Current (A) 3 1 3 3 10 Current Sensitivity (pA) 0. The PXIe-4136 system source measure unit (SMU) delivers high power, precision, and speed and features 4-quadrant operation. pdf ⭳ Download pdf. 7 PXIe-4467—NI-DAQmx. Radwell is not an authorized distributor, reseller or representative of the products featured on this website. View and Download NI PXIe-4136 getting started manual online. Download. PXIe, ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit. Please contact Artisan Technology Group Sales for configuration pricing and availability. Part Number(s): 786320-01 | Read More . Description. 8 ms/s isolated digitizer, l and c measurement support, pxi digital multimeter (28 pages). PXIe-4136 (783760-01) PXI Express: 1: 20 W: 12 W-200 V to 200 V:PXIe-4162 - Price and Info. The PXIe-8840 includes two 10/100/1000BASE-TX (Gigabit) Ethernet ports, two USB 3. PXIe-2529 Dimensional Drawing(s)Price does not include local taxes (GST) or delivery charges. It is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. 請注意,如果機箱本身是PXI機箱而不是PXIe,則任何插槽中都無法相容任何樣式的PXIe卡。. PXIe, 7½-Digit, ±1,000 V, Onboard 1. ). Repair Evaluation: $150. 1 Offset Accuracy, Tcal +/- 5 degrees (pA) 6 200 100 200 100 Offset Accuracy, Tcal +/- 1 degree (pA) 5 - 40 - 40The National Instruments NI PXIe-1078 is In Stock & Ready to Ship at Apex Waves. The PXIe-6355 offers analog I/O, digital I/O, and counter/timers in a single PXI module. 2770-784068-01. It is a test and measurement platform that combines a controller with measurement instruments in a multi-slot chassis. This adapter is rated for 60 V DC maximum voltage and is not a recommended accessory for the PXIe-4136 or PXIe-4137 due to the 200 V DC output of those SMUs. Description. It includes the Digital Pattern Editor for configuring pin maps, specifications, levels, timing, and patterns. The actual product may differ from image shown. It is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. The PXIe-6509 can directly drive external digital devices such as solid-state relays (SSRs). 39000: $7,725. 2 TB of NVME SSD storage in a single PXI Express slot. This document explains how to install, configure, and test the NI PXIe-4136/4137 (NI 4136/4137). Price does not include local taxes (GST) or delivery charges. 9 W of power for 0°C to 55 °C. NI PXI Waveform Generator Bundle. The latest PCI Express Gen 3 switches deliver higher data throughput, the latest Intel multicore processors facilitate. PXIe-4138. Manufacturer; Product introduction. PXIe, ±200 V, ±1 A DC, 20 W DC, 1 pA System PXI Source Measure Unit. PXIe, ±200 V, ±1 A DC, 20 W DC, 1 pA System PXI Source Measure Unit The PXIe-4136 system source measure unit (SMU). com | PXIe-4136 Specifications Maximum measure rate to host 1. 1 1 0. Farnell Ireland offers fast quotes, same day dispatch, fast delivery, wide inventory, datasheets & technical support. The NI PXIe-4136 has Free Ground Shipping. It offers analog I/O, digital I/O, four 32‑bit counters, and analog and digital. Price may vary with addition of accessories and services. PXIe-4139, PXIe-4141) 05-10-2022 06:36 PM. com. PXIe-4162 configured for normal transient response. Platform. PXIe-8822/42/62 Specifications "Windows 10 IOT or Windows 11 IOT or Linux RT"PXI/PXIe Module Providing Up to 2 Channels of 5/6-Wire Resolver Simulation. Learn more about its features and specifications on this webpage. Technical Documents (0) Available to manufacturer lead time 9 weeks. com Amplicon. g) Ensure that there is no exposed wiring, cable ground shield, or drain wire in the shaded region: 8. Contact us with questions for pricing. 09. Contact us with questions for pricing. PXIe-4136 200 V, 1 A System PXI Source Measure Unit 7KHVHVSHFLILFDWLRQVDSSOWRWKH3;,H ˇ Contents 'HILQLWLRQV技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。8 | ni. PXIe-4136. The reference clock frequency for the PXIe 5413 PXI Waveform Generator is 100 MHz (<±25 ppm) and the sample clock rate is 800 MHz. PXIe-4136 Home PXIe-4136. The module supports DMA streaming between the host PC and SMU, so you can stream. 1 1 0. Electrical. We’ve been in this industry for more than 18 years selling new and used National Instruments units with hundreds of models as PXIE controllers: PXIE-8133, PXIE-8135, PXIE-8840 and etc. Solution. Table of contents . PXIe, ±200 V, ±1 A DC, 20 W DC, 1 pA System PXI Source Measure Unit. The device is equipped with a four-wide 3U PXI Express module. PXIe-4163. Buy 786818-01 - Ni - Banana Jack Adapter, PXIe-4136/7/8/9 SMUs. SMU specifications take precedence if the SMU model is rated for lower voltage. Software: Includes interactive soft front panel, API support. You can configure each line for input or output and you also can configure each line with a user-configurable pull-up or pull-down resistor. Price does not include custom duties and taxes. 01 1 0. 通常當發生此錯誤時,不正確的連接包括反轉檢測端子的極性、將檢測引線短接在一起或本地檢測 HI 或 LO 的連接鬆動。. com | PXIe-4137 Calibration Procedure. Farnell UK offers fast quotes, same day dispatch, fast delivery, wide inventory, datasheets & technical support. 5 Replies 361 Views 0 Kudos. National Instruments PXIe-5645 / PXIe-5645R PXI Vector Signal Transceiver. National Instruments PXIe-4142 Source Measure Unit (SMU)Configuration: Number of SMU Channels: 4 Voltage Range: -24 V to 24 V Current Range: -150 mA to 150 mA Current Sesitivity: 100 pA Source Adapt: No Part Number: 782430-01Please contact Artisan Technology Group Sales for configuration pricingSolution. Price may vary with addition of accessories and services. 6 (patch) PXIe-4302: TB-4302: PXIe. 例如,NI PXIe-4139 SMU 與 NI InstrumentStudio™ 2022 一起用於測量 LED 的 IV 曲線。目標客群是需要對二極體、太陽能電池、LED 和電晶體等元件進行故障分析和參數特性的用戶。此範例將展示如何配置 InstrumentStudio™ 單通道掃描,它以所配置的電壓間隔來掃描並測量相應. One Year Warranty. Contact us with questions for pricing. Category. 1-Slot, 100 MVector/s PXI Digital Pattern Instrument. Additional Resources. The digitizer functionality of NI SMUs is essential for capturing detailed transient characteristics of the SMU response or for characterizing device under test (DUT) behavior such as line. Aerospace, Defense, & Government. We would like to show you a description here but the site won’t allow us. The PXIe‑4136 is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. National Instruments PXIe-4309 Flexible Resolution PXI Analog Input Module. 4 Noise bandwidth is limited to 10 kHz and measured at 20 mA into a 500 Ω load. Preparing the Environment. 1 1 0. It is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. 1 1 0. Adjustment—Adjust the calibration constants of the PXIe-4136. PXIe-4135 PXIe-4136 PXIe-4137 PXIe-4138 PXIe-4139 Maximum Voltage (V) 200 200 200 60 60 Maximum DC Current (A) 1 1 1 3 3 Maximum Pulse Current (A) 3 1 3 3 10 Current Sensitivity (pA) 0. 1 Offset Accuracy, Tcal +/- 5 degrees (pA) 6 200 100 200 100 Offset Accuracy, Tcal +/- 1 degree (pA) 5 - 40 - 40 PXIe, ±200 V, ±1 A DC, 20 W DC, 1 pA System PXI Source Measure Unit The PXIe-4136 system source measure unit (SMU) delivers high power, precision, and speed and features 4-quadrant operation. National Instruments PXIe-4141 Source Measure Unit (SMU) •Number of SMU Channels: 4 •Voltage Range: -10 V to 10 V •Current Range: -100 mA to 100 mA •Current Sesitivity: 10 pA •Source Adapt: Yes Part Number: 150660B-02L. The PXIe-5413 is a 20 MHz arbitrary waveform generator capable of generating user-defined, arbitrary waveforms and standard functions including sine, square, triangle, and ramp. Ideal for the simulation of variable differential transformers (VDT), both linear (LVDT) and rotary (RVDT) types, as well as Resolvers. PXIe, ±200 V, ±1 A DC, 20 W DC, 1 pA System PXI Source Measure Unit The PXIe-4136 system source measure unit (SMU) delivers high power, precision, and speed and features 4-quadrant operation. It is a hardware-timed instrument with a high-speed sequencing engine for synchronizing. PXIe-4309 - Price and Info. Source Measure Unit SMU, 24- Channel, 4-Quadrant, PXIe-4163, ± 50mA, ± 24V, 1. The block diagram for the signal calculation is shown by the. secure the SA-413B onto a PXIe-4136/4137/4138/4139 using the two retaining screws to a torque of 0. pxie-4136系统源测量单元(smu)具有高功率、高精度和高速度等优点,并采用四象限运行模式。该设备是一款具有高速序列生成引擎的硬件定时仪器,用于同步多个smu之间的采集。该模块支持上位机和smu之间的直接dma数据流,使您能够以仪器的最大更新速率和采样率. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Price may vary with addition of accessories and services. GETTING STARTED GUIDE NI PXIe-4136/4137 Single-Channel System Source Measure Unit (SMU) Note Before you begin, install and configure your chassis and controller. 2-3U PXI Express storage unit provides up to 15. Qty Unit Price Ext Price; 1: $7,725. e. Additional information. It is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. e絡盟 Hong Kong offers special pricing, same day dispatch, fast delivery, wide inventory, datasheets & technical support. It is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. The NI 4136 is a single-channel system source measure unit (SMU). 這些卡監控 HI 和 HI SENSE 之間的電壓差,如果. Driver support for the modules was first available in the following NI-DAQmx versions: PXIe-4466—NI-DAQmx 20. The following table lists the minimum current levels of SMU devices. PXIe-1095 This document contains specifications for the PXIe-1095 chassis. Manufacturer: NI. •Current Range: -500 mA to 500 mA. Standard Package. Please contact Artisan Technology Group Sales for configuration pricing and availability. PXIe-4135 PXIe-4136 PXIe-4137 PXIe-4138 PXIe-4139 Maximum Voltage (V) 200 200 200 60 60 Maximum DC Current (A) 1 1 1 3 3 Maximum Pulse Current (A) 3 1 3 3 10 Current Sensitivity (pA) 0. Source Measure Unit PXI di sistema, ±200 V, ±1 A CC, 20 W CC, 1 pA, PXIe. More info on our Help Legislation page. More info on our Help Legislation page. Distributor of NI PXIe-4136 PXI Source Measure Unit (1 Channel, DC ±200V/±1A, 1 pA) NI Call for best price. The PXIe‑1071 accepts PXI Express modules or standard PXI hybrid. PXIe-5450 PXIe-5611 2x PXIe-5651 PXIe-5601 + MORE! $9,774. : 13AJ4107. are not included with this equipment unless listed in the above stock item description. National Instruments PXIe-1082 PXI Chassis. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research. 3 Noise is measured from 20 Hz to 20 MHz at output voltages of 0. Electrical The following section provides information about the PXIe-1095 AC input and DC output. A valid service agreement may be required. •Current Sesitivity: 100 fA. (24 reviews) " The Crucial T700 2TB Gen 5 NVMe SSD is the fastest consumer SSD currently available. Price may vary with addition of accessories and services. Buy 784068-01 - Ni - Screw Terminal Connector Kit, PXIe-4136/7/8/9 SMUs. Please contact Artisan Technology Group Sales for configuration pricing and availability. Other Names. versions of the PXIe-4137 unless otherwise specified. NI 4136/4137 Output Connector. 06 GHz, Quad-Core, Intel Core i7-820QM Embedded Controller for PXI and CompactPCI frameworks. 3 FP32 TFLOPs and a Total Graphics Power (TGP) of 58W. Figure 5. National Instruments PXIe-4137 Source Measure Unit (SMU) Configuration: •Number of SMU Channels: 1. PXIe-4163 Driver. Click here to sell your equipment! More Information. PXIe-4145 PXIe-4162 PXIe-4163 Issue Details I would like to simulate battery cells connected in series using SMU-s. Buy 786818-01 - Ni - Banana Jack Adapter, PXIe-4136/7/8/9 SMUs. These high-availability features improve the mean time between failure (MTBF) and mean time to repair (MTTR) of the PXI system. The PXIe-4468 helps you make precision measurements with microphones, accelerometers, and other transducers that feature large dynamic ranges. At VTI, we manufacture chassis that are compatible with all PXI Express and PXI hybrid cards. Fax: (240) 376-1381. 1 Year Warranty. Note: only the PXIe-414x, PXIe-4136/4137, and PXIe-4138/9 will allow you to set the current level to 0; all other NI SMUs have a minimum current level, typically 2% of the current range. 9 To recover within ±20 mV after a load current change from 10% to 90% of range. The actual product may differ from image shown. Because of this software-designed approach, the PXIe-5644 features the flexibility of a software defined radio architecture with RF instrument class. Price may vary with addition of accessories and services. The PXIe‑5114 low-cost PXI oscilloscope has two channels that sample up to 250 MS/s with flexible settings for coupling, impedance, voltage range, and filtering. Source Measure Units and LCR Meters. 除了參考規格表之外,一種快速確定機箱中哪些卡可以工作的方法. The Trifecta A2000 GPU supports 8GB of GDDR6 memory, up to 8. Could you try going through those steps and seeing if that allows you to reset the safety interlock? If going through the safety interlock test in step 5 above fails, your PXIe-4136 SMU may be damaged. PXIe, -200 V, -1 A (DC)/-3 A (Pulsed), 1 pA / 100 fA Precision System PXI Source Measure Unit. Call. PXIe, ±200 V, ±1 A DC, 20 W DC, 1 pA System PXI Source Measure Unit The PXIe-4136 system source measure unit (SMU) delivers high power, precision, and speed and features 4-quadrant operation. Output Connector Assembly 3.